# Carbon negative geothermal: Theoretical efficiency and sequestration potential of geothermal-BECCS energy cycles

- **Authors:** K.A. Titus; D.E. Dempsey; R.A.M. Peer
- **Journal:** International Journal of Greenhouse Gas Control, vol. 122, pp. 103813 (2023)
- **Publisher:** Elsevier BV
- **DOI (version of record):** [https://doi.org/10.1016/j.ijggc.2022.103813](https://doi.org/10.1016/j.ijggc.2022.103813)
- **This page:** https://ddempsey.github.io/papers/2023-titus-carbon-negative-geothermal-theoretical-efficiency/
- **Open PDF:** [https://ddempsey.github.io/papers/2023-titus-carbon-negative-geothermal-theoretical-efficiency/titus2023-carbon-negative-geothermal.pdf](https://ddempsey.github.io/papers/2023-titus-carbon-negative-geothermal-theoretical-efficiency/titus2023-carbon-negative-geothermal.pdf) (Accepted manuscript (peer-reviewed, author's version))
- **Full text (Markdown):** [https://ddempsey.github.io/papers/2023-titus-carbon-negative-geothermal-theoretical-efficiency/fulltext.md](https://ddempsey.github.io/papers/2023-titus-carbon-negative-geothermal-theoretical-efficiency/fulltext.md)
- **Notice:** Accepted manuscript. © 2023. This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/. The version of record is available at https://doi.org/10.1016/j.ijggc.2022.103813
- **Explainer:** all explainers on this site are AI-generated.
- **BibTeX:** https://ddempsey.github.io/papers/2023-titus-carbon-negative-geothermal-theoretical-efficiency/citation.bib
- **Topics:** Geothermal systems; CO2 & hydrogen storage
- **Keywords:** Environmental science; Waste management; Geothermal gradient

## In brief

We modelled four power plant designs that burn forestry waste alongside a 160 °C geothermal resource and dissolve the flue CO2 in reinjected water. Per kg/s of geofluid drawn, they generated 62–589 kWe, the top figure mostly from biomass, and could store 217–675 tonnes of CO2 a year.

- In our model, adding a biomass boiler increased output per kg/s of 160 °C geofluid from 32–43 kWe in conventional plants to 62–76 kWe.
- A biomass steam plant that uses geofluid to preheat its water generated 589 kWe per kg/s of geofluid and needed 19% less biomass than the same plant without geofluid.
- Water reinjected at 95 °C and 50 bar can dissolve 0.021 kg of CO2 per kg, enough for all the flue CO2 of three designs and 17% of the fourth.
- We estimate operational emissions intensities of −131 to −922 g of CO2 per kWh, where negative means more CO2 is stored than emitted.
- Scaled up, a 124 MWe plant of Configuration 3, which splits biomass-heated geofluid between a steam turbine and a binary unit, could sequester 1 Mt of CO2 a year.

## The problem

About 70% of the world's geothermal systems are low or medium enthalpy, with
reservoirs cooler than 160 °C (Franco and Villani, 2009; Hochstein, 1990).
Their low electricity yield often makes them uneconomic to develop. One way to
increase the yield is to add a second heat source, such as biomass (DiPippo,
2016). Burning biomass is usually treated as carbon neutral, because the plants
took that carbon from the atmosphere as they grew. Capturing and storing that
CO2 then removes it from the atmosphere. This is bioenergy with carbon capture
and storage (BECCS).

Free-phase CO2 injected in conventional storage is buoyant and could leak
unless the caprock is shown to be secure (Kaya and Zarrouk, 2017; Kervévan et
al., 2013). Water with dissolved CO2 is denser than fresh water and contains no
buoyant free-phase CO2 (Sigfusson et al., 2015). At Hellisheidi in Iceland, CO2
from the geothermal fluid is already dissolved in reinjected water (Sigfússon
et al., 2018). Our goal was to combine biomass heating with this form of
storage: burn biomass to generate more power, then dissolve the flue CO2 in the
reinjected geofluid. We call this geothermal-BECCS.

## What we did

We built a systems model of mass and energy balances for each plant. Each
design draws 1 kg/s (kilogram per second) of geofluid from a reservoir at 160
°C and 50 bar. The results can therefore be scaled to larger plants, although
we did not consider how infrastructure or costs change with size. The fuel is
forestry waste from Kaingaroa Forest in New Zealand. Reinjected water leaves
the plant at an average of 95 °C and takes up CO2 at 50 bar, 50 times the 1 bar
surface pressure in our model. At these conditions, water dissolves up to 0.021
kg of CO2 per kg (2.1 wt%).

We compared four hybrid designs with three benchmarks. Biomass superheats the
steam of a flash plant in Configuration 1, and evaporates the working fluid of
an organic Rankine cycle (ORC) binary plant in Configuration 2. In
Configuration 3, biomass heats the geofluid before it is split between a steam
turbine and a binary unit. Configuration 4 is a biomass steam plant that uses
geofluid to preheat its water. Benchmarks A and B are conventional flash and
binary plants. Benchmark C is a biomass plant with no geofluid.

## What we found

In our model, every hybrid design generated more power than the geothermal
benchmarks. Per kg/s of geofluid, the flash and binary benchmarks generated 32
and 43 kWe (kilowatts of electricity). Configurations 1, 2 and 3 generated 64,
76 and 62 kWe, at utilisation efficiencies of 9, 9 and 7%, against 6 and 8% for
the benchmarks. Configuration 4 generated 589 kWe at 20% efficiency, the same
power as Benchmark C from 19% less biomass. However, Configuration 3 almost
doubled the power of the flash benchmark but was only 1 percentage point more
efficient, and less efficient than the binary benchmark.

Configurations 1, 2 and 3 emit 0.007–0.016 kg/s of flue CO2. The reinjected
water can dissolve up to 0.021 kg/s. All of it is therefore dissolved.
Configuration 4 emits 0.127 kg/s, about six times that capacity. Only 17% of
its CO2 is therefore stored. We count the rest as carbon neutral. Configuration
4 still stores the most CO2 per kg/s of geofluid, 675 tonnes a year, against
217–501 tonnes for the other three.

Per unit of electricity, Configuration 4 stores the least. This is because most
of its power comes from biomass, while the CO2 it can store is limited by its 1
kg/s of reinjected water. We estimate emissions intensities of −386, −753, −922
and −131 g of CO2 per kWh for Configurations 1 to 4. Average US natural gas and
coal plants emitted 413 and 1012 g per kWh in 2021 (EIA, 2021). These values
count operational emissions only.

<div class="widget" id="w-gbeccs" role="group" aria-label="Geofluid, biomass and CO2 sequestration for a geothermal-BECCS plant of chosen configuration and size, with its emissions intensity compared against operating power plants"></div>

Scaled to 100 MWe (megawatts of electricity), as in the widget, Configuration 3
would need 1613 kg/s of geofluid and 29 kg/s of biomass, and could sequester
0.8 Mt (million tonnes) of CO2 a year. Configuration 4 would need 170 kg/s of
geofluid and could sequester 0.11 Mt a year. Its geofluid demand is about 6% of
the take at the 175 MWe Wairakei field (Wymer and Nicholson, 2014). To
sequester 1 Mt a year, Configuration 3 would need a rating of 124 MWe. In
practice, a site's geothermal and biomass resources would have to be estimated
before a plant could be sized.

## Limitations

The model treats the geofluid as pure water, with no magmatic CO2. Geofluid at
Rotokawa can hold up to 0.35 wt% magmatic CO2 (Addison et al., 2015b). If
captured and reinjected, this would use about a sixth of Configuration 4's
dissolution capacity. Its sequestration would fall by the same amount. We also
neglected parasitic loads, the power a plant uses to run itself, because our
modelled plants are small. For Configuration 4, CO2 compression and pumping
would use under 1% of output. However, a full-sized plant would need all of its
parasitic loads optimised.

A decline in reservoir pressure could form buoyant free-phase CO2 that poses a
leakage risk (Kaya and Zarrouk, 2017). Access to a sustainable biomass supply
is also likely to limit where these plants can be built. We have not costed the
designs. The economic feasibility of a particular site will need further
analysis of electricity, feedstock and CO2 sequestration markets.

## Glossary

**Enthalpy** is the heat content of a fluid. Low and medium enthalpy systems
have reservoir temperatures below 160 °C.

**Geofluid** is the hot water and steam produced from a geothermal reservoir.

A **flash plant** lowers the pressure of geofluid so that part of it boils to
steam that drives a turbine.

A **binary plant** passes heat from the geofluid to a second working fluid in a
closed loop. An **organic Rankine cycle (ORC)** plant uses an organic working
fluid, here isopentane.

**Superheating** heats steam above its boiling temperature. **Preheating**
warms a liquid before it is boiled.

**BECCS** (bioenergy with carbon capture and storage) burns biomass for energy
and stores the resulting CO2 underground.

**Flue CO2** is the CO2 in the exhaust gas from a boiler.

**Reinjection** returns used geofluid to the reservoir through wells.

**Free-phase CO2** is CO2 stored as a separate liquid or supercritical fluid,
undissolved in water.

A **caprock** is a low-permeability rock layer above a reservoir that limits
upward flow.

**kg/s** is kilograms per second. **kWe** and **MWe** are kilowatts and
megawatts of electricity.

**Exergy** is the part of a fluid's or fuel's energy that could in principle be
converted to work, given the surrounding temperature and pressure.

**Utilisation efficiency** is net electrical power divided by the exergy
supplied by the geofluid and biomass.

**wt%** is the mass of dissolved CO2 as a percentage of the mass of water.

**Emissions intensity** is the mass of CO2 emitted per kilowatt-hour (kWh) of
electricity. A negative value means more CO2 is stored than emitted.

**Mt** is millions of tonnes.

**Magmatic CO2** is CO2 of volcanic origin already dissolved in the geofluid.

A **parasitic load** is power used by the plant itself, for example to run
pumps and compressors.

## Cite

Titus, K.A., Dempsey, D.E., Peer, R.A.M. (2023). Carbon negative geothermal: Theoretical efficiency and sequestration potential of geothermal-BECCS energy cycles. International Journal of Greenhouse Gas Control, 122, 103813. https://doi.org/10.1016/j.ijggc.2022.103813

```bibtex
@article{titus2023carbon,
  title = {Carbon negative geothermal: Theoretical efficiency and sequestration potential of geothermal-BECCS energy cycles},
  author = {Titus, K.A. and Dempsey, D.E. and Peer, R.A.M.},
  journal = {International Journal of Greenhouse Gas Control},
  year = {2023},
  volume = {122},
  pages = {103813},
  publisher = {Elsevier BV},
  doi = {10.1016/j.ijggc.2022.103813},
  url = {https://ddempsey.github.io/papers/2023-titus-carbon-negative-geothermal-theoretical-efficiency/}
}
```